The following tables describe the methods used to calculate pressure, temperature and flow data reported by ORION LTE, LTE-M, LTE-MS and ORION Cellular C endpoints.
- ORION LTE, LTE-M and ORION Cellular C endpoints offer integrated temperature sensors.
- When connected to E-Series G1 Ultrasonic Meters, ORION LTE, LTE-M, LTE-MS and ORION Cellular C endpoints return water pressure, water temperature, meter ambient temperature and endpoint temperature data.
- When connected to E-Series F2 Ultrasonic Meters, ORION LTE, LTE-M, LTE-MS and ORION Cellular C endpoints return water pressure, water temperature, meter ambient temperature, endpoint temperature and max flow data.
Sensor data is displayed on Monitor page cards and can be exported using:
- EDS v2 Range, Flow, Leak and Read APIs.
- Export Fieldsets to extend the default fields of a Latest Read export or a Date Range export from the Monitor page.
Monitor page Latest Read Export |
Average (7 Day) | Min (7 Day) | Max (7 Day) | Last Reported | Latest Average |
Water Pressure | The average of every sample taken during the previous 7 days. | The lowest pressure measured during the previous 7 days. | The highest water pressure measured during the previous 7 days. | Date and timestamp of the last reported water pressure value. | Average pressure taken during the last 15 minutes. |
Water Temp. | The average of every sample taken during the previous 7 days. | The lowest water temp measured during the previous 7 days. | The highest water temp measured during the previous 7 days. | Date and timestamp of the last reported water temp value. | Average water temp taken during the last 15 minutes. |
Meter Ambient Temp. | The average of every sample taken during the previous 7 days. | The lowest meter ambient temp measured during the previous 7 days. | The highest meter ambient temp measured during the previous 7 days. | Date and timestamp of the last reported meter ambient temp value. | Latest sample from the sensor. |
Endpoint Temp. | The average of every sample taken during the previous 7 days. | The lowest endpoint temp measured during the previous 7 days. | The highest endpoint temp measured during the previous 7 days. | Date and timestamp of the last reported endpoint temp value. | Latest sample from the sensor. |
Flow Rate (Requires E-Series Ultrasonic G2 Ultrasonic meters.) |
N/A | N/A | The highest flow rate measured during the previous 7 days. | Date and timestamp of the last reported max flow rate. | N/A |
Condition (Returned via export.) |
Increasing = The current value is greater than the 7-day average. Decreasing = The value is less than the 7-day average. |
Monitor page Date Range Export |
Average | Min | Max | Read Time |
Water Pressure | Average pressure taken during the selected timeframe. | The lowest pressure measured during the selected timeframe. | The highest pressure measured during the selected timeframe. | Date and timestamp of the last reported water pressure value. |
Water Temp. | Average water temp taken during the selected timeframe. | The lowest water temp measured during the selected timeframe. | The highest water temp measured during the selected timeframe. | Date and timestamp of the last reported water temp value. |
Meter Ambient Temp. | Average meter ambient temp taken during the selected timeframe, except for 15 minute interval data, which uses a single sample. | The lowest ambient water temp measured during the selected timeframe, except for 15 minute interval data, which uses a single sample. | The highest water temp measured during the selected timeframe, except for 15 minute interval data, which uses a single sample. | Date and timestamp of the last reported meter ambient temp value. |
Endpoint Temp. | Average endpoint temp taken during the selected timeframe, except for 15 minute interval data, which uses a single sample. | The lowest endpoint temp measured during the selected timeframe, except for 15 minute interval data, which uses a single sample. | The highest endpoint temp measured the selected timeframe, except for 15 minute interval data, which uses a single sample. | Date and timestamp of the last reported endpoint temp value. |
Flow Rate (Requires E-Series Ultrasonic G2 Ultrasonic meters with v1.0.4250 or later firmware .) |
N/A | N/A | The highest flow rate measured during the selected timeframe. | Date and timestamp of the last reported max flow rate. |
EDS v2 Range, Flow, Leak and Read APIs | Average | Min | Max |
Water Pressure | Average pressure taken during the selected timeframe. | The lowest pressure measured during the selected timeframe. | The highest pressure measured during the selected timeframe. |
Water Temp. | Average water temp taken during the selected timeframe. | The lowest water temp measured during the selected timeframe. | The highest water temp measured during the selected timeframe. |
Meter Ambient Temp. | Average meter ambient temp taken during the selected timeframe, except for 15 minute interval data, which uses a single sample. | The lowest ambient water temp measured during the selected timeframe, except for 15 minute interval data, which uses a single sample. | The highest water temp measured during the selected timeframe, except for 15 minute interval data, which uses a single sample. |
Endpoint Temp. | Average endpoint temp taken during the selected timeframe, except for 15 minute interval data, which uses a single sample. | The lowest endpoint temp measured during the selected timeframe, except for 15 minute interval data, which uses a single sample. | The highest endpoint temp measured the selected timeframe, except for 15 minute interval data, which uses a single sample. |